ACCUREX Triglycerides 125
Buy Infinite Liquid Triglyceride 125 Diagnostic Reagent (Pack Size: 5 X 25 ml) from Accurex. Liquid Triglycerides reagent kit is used for determination of triglycerides, based on enzymatic methods using Lipoprotein lipase, Glycerol kinase, Glycerol phosphate oxidase and Peroxidase.
Triglyceride Reagent is a ready to use reagent & can be determined in just 10 minutes at 37°C or 20 minutes at Room Temperature (25°C – 30°C). The Triglyceride kit should be stored at 2- 8°C and is stable till the expiry date indicated on the label. Triglycerides normal range is Less than 150 milligrams per deciliter (mg/dL) or less than 1.7 millimoles per liter (mmol/L).
- 100% after sales service.
- 7 Day Replacement Policy
- Hassel Free Cancellations
- Cash On delivery
- Minimum 6 Months of Shelf life (Applicable on Reagent, Chemical & Kits)
Description
- Infinite Liquid Triglycerides 125 is a reagent set for determination of triglycerides, based on enzymatic methods using Lipoprotein lipase, Glycerol kinase, Glycerol phosphate oxidase and Peroxidase.
- Infinite Liquid Triglycerides 125 is a ready to use reagent.
- Triglycerides 125 can be determined in just 10 minutes at 37°C or 20 minutes at R.T. (25°C – 30°C).
- Infinite Liquid Triglycerides 125 is linear up to 800 mg%.
- Infinite Liquid Triglycerides 125 can be used on any Colorimeter, Spectrophotometer, Discrete semi automated and Automated analyzer. Programme can be designed for any specific analyzer upon request.
- The influence of lipids, haemolysis and bilirubin (up to 8 mg%) is negligible.
Method – GPO-POD
Pack Size : 5 x 25 ml
Glycerol released from hydrolysis of triglycerides by lipoprotein lipase is Converted by glycerol kinase into glycerol- 3- phosphate which is oxidized by glycerol phosphate oxidase to dihydroxyacetone phosphate and hydrogen peroxide. In presence of peroxidase, hydrogen peroxide oxidizes phenolic chromogen to a red coloured compound.
Reaction type ………… ………. End-Point
Reaction time …. 10 mins. at 37°C/20 mins. at R.T. (25-30°C)
Wavelength ……….. ………… 510 nm. (500 – 530 nm.)
Zero setting with ………………….. Reagent Blank
Blank absorbance limit ………… < 0.300 Abs.
Sample volume …………………………… 0.01 ml (10 jul)
Reagent volume ……….. …………. 1.0 ml
Standard concentration .. …………… 200 mg%
Linearity ………………… 800 mg/dl
The kit should be stored at 2- 8°C and is stable till the expiry date indicated on the label.
The reagent and standard are ready-to-use and are stable till expiry, when stored at 2-8°C. DO NOT FREEZE THE REAGENT.
The reagent should be stored only in the amber bottle provided to protect it from direct light. Before use swirl in the reagent gently. DO NOT SHAKE VIGOROUSLY.
Over time, the reagent may develop a light pink color. This is expected and does not affect the reagent performance. Discard the reagent if the absorbance of the same exceeds 0.300O.D. against distilled water at 510 nm.
Contamination of the reagent should be strictly avoided. Should the
reagents develop turbidity and discard the reagent.
Over time, the reagent may develop a light pink color. This is expected and does not affect the reagent performance. Discard the reagent if the absorbance of the same exceeds 0.300O.D. against distilled water at 510 nm.
Contamination of the reagent should be strictly avoided. Should the
reagents develop turbidity and discard the reagent.










Reviews